Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13693825

- Product Categories
- Friendly Links
Information Name: | Low temperature chiller maintenance - Kelly Refrigeration 1 |
Published: | 2015-04-09 |
Validity: | 30 |
Specifications: | Low temperature chiller |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Low temperature chiller Contact: Lei Meifei QQ: 374867563 Mobile: 13751045062 Website: www.karezl.com low temperature chiller Dimensions is a low temperature chiller water cooling equipment, which can supply a constant temperature, constant current, constant voltage cooling equipment. Chiller is written in a certain amount of water inside the water tank of the machine, refrigeration system through water cooling, then there is a circulating pump inside the machine will be written into the freezing water needed to cool the equipment, chilled water heat inside the device away, then hot water flows to cool the tank again. Ultra-low temperature refrigeration refrigeration scale: less than -253 ℃; deep cooling:? -120 ~ -253 ℃; ordinary refrigeration: more than -120 ℃. Key Features (1), the unit compressor selection of imported low-temperature compressor; (2), the use of refrigerants such as R404A, R410a, R22 / R407C so satisfied refrigeration temperature and environmental needs; (3), the temperature scale selection: can Chilled water supply of skills between -5 ℃ ~ -60 ℃ (user based on different production needs, the selection is not the same water temperature unit standard) (4), based on the user's needs, you can choose a variety of coolants (chilled water ): glycol solution, alcohol, and other ternary mixed solution of alcohol contained in the refrigerant, but also according to the evaporator corrosion requires planning, use calcium chloride solution; (5), according to 24 hours continuous machine operation planning, can be satisfied all kinds of production skills with a series of cold source; (6), the unit can be cold water tank and circulating pump comes without cooling tower and cooling water pump, installation and maintenance simple and convenient; (7), equipped with various types of safety devices, function stability, low noise, long life use, simple operation; use LCD interface, fast and simple operation, operating conditions glance; refrigeration operation principle is the choice must approach within a certain period of time and space, so that a or space reaches a lower temperature than the ambient medium, and maintained within a given temperature scale. To make an object or space must reach or maintain a low temperature, it must choose the means and skills must approach after another to remove the heat of an object or space, the choice of surgical skills called refrigeration skills. Usually learn environmental media or objects heat and transfer it to the target is higher than the ambient temperature of the heating process, called heat pump heating. About extracts heat from the ambient medium and cooling system to remove heat at high temperatures, alternately or together to complete the two functions of refrigeration and heating and cooling machine called for heat pumps. From the concept of energy usage point of view, this is an effective approach to the use of energy, used both refrigeration, and use the heat. Refrigeration and heat pump cycle is the principle and method of calculation is similar. Applicable scale low temperature chiller used: widely used in rubber, plastics, petroleum, chemical, electronics, paper, textiles, brewing, pharmaceutical, food, machinery, beverage, vacuum coating, plating, central air conditioning and many other areas, but also throughout together Cooling methods used to gather, will facilitate the manifold. Low temperature chiller can be customized into acid-type models, fit the special needs of special skills of customers, but also can be customized to low temperature models, with low temperature coolants, has reached the special needs of special skills of the customer. Ethylene glycol chiller chiller manufacturer glycol chiller manufacturer direct factory price brand ethylene glycol chiller chiller chiller principle role glycol ethylene glycol chiller factory direct cold water Service glycol chiller unit maintenance ethylene glycol chillers wholesale joined glycol chillers agent glycol chillers price glycol chiller chiller uses ethylene glycol chillers structure chillers installation |
Admin>>>
You are the 8188 visitor
Copyright © GuangDong ICP No. 10089450, Hunan Kelly Refrigeration Equipment Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8188 visitor
Copyright © GuangDong ICP No. 10089450, Hunan Kelly Refrigeration Equipment Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility